OEM China Troponin Levels In Myocarditis Exporter – Myoglobin test – Laihe

OEM China Troponin Levels In Myocarditis Exporter – Myoglobin test – Laihe


Sample type:

    Product Advantage:

    • High Detection accuracy
    • High cost performance
    • Quality assurance
    • Fast delivery
    We consistently execute our spirit of ''Innovation bringing progress, Highly-quality ensuring subsistence, Administration advertising and marketing gain, Credit history attracting buyers for Troponin I High Sensitive Test, Troponin T Normal Value, Trop Blood Test, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software development are our distinguishing feature.
    OEM China Troponin Levels In Myocarditis Exporter –Myoglobin test – LaiheDetail:

    adv_img

    Allow the test, specimen and/or controls to reach room temperature (15-30°C) priorto testing.

    1. Bring the pouch to room temperature before opening it. Remove the test device fromthe sealed pouch and use it as soon as possible.Best results will be obtained if the test is performed immediately after opening the foil pouch.

    2. Place the test device on a clean and level surface.
    For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops ofserum or plasma (approximately 50 uL) to the specimen well (S) of the test device,then start the timer. See illustration below.
    For Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer4 drops of venipuncture whole blood (approximately 100 uL) to the specimen well(S) of the test device,then start the timer. See illustration below.
    For Finaerstick Whole Blood specimens:
    To use a capillary tube: Fill the capillary tube and transfer approximately 100 uL of fingerstick whole blood specimen to the specimen well (S) of the test device,then start the timer.See illustration below.
    To use hanging drops: Allow 4 hanging drops of fingerstick whole bloodspecimen (approximately 100 uL) to fall into the center of the specimen well(S)on the test device,then start the timer. See illustration below.

    3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes.


    Product detail pictures:


    Related Product Guide:

    We retain bettering and perfecting our merchandise and service. At the same time, we do the job actively to do research and improvement forOEM China Troponin Levels In Myocarditis Exporter –Myoglobin test – Laihe, The product will supply to all over the world, such as: kazakhstan, Poland, Singapore, Due to the stability of our items, timely supply and our sincere service, we are able to sell our merchandise not only over the domestic market, but also exported to countries and regions, including the Middle East, Asia, Europe and other countries and regions. At the same time, we also undertake OEM and ODM orders. We will do our best to serve your company, and establish a successful and friendly cooperation with you.
    email TOP
    privacy settings Privacy settings
    Manage Cookie Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    ✔ Accepted
    ✔ Accept
    Reject and close
    X