Sample type:

    Product Advantage:

    • High Detection accuracy
    • High cost performance
    • Quality assurance
    • Fast delivery
    We attempt for excellence, provider the customers", hopes to be the most beneficial cooperation team and dominator enterprise for staff, suppliers and shoppers, realizes value share and continuous advertising for Troponin Levels In Heart Failure, covid antigen self test kit, novel coronavirus test kit, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
    OEM China Reason For High Troponin Levels Supplier –CK-MB test – LaiheDetail:

    WechatIMG1795

    Directions For Use

    Allow the test, specimen and/or controls to reach room temperature (15-30C) priorto testing.

    1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.Best results will be obtained if thetest is performed immediately after opening the foil pouch.

    2. Place the test device on a clean and level surface.
    For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops ofserum or plasma (approximately 50 uL) to the specimen well (S) of the test device,then start the timer. See illustration below.

    For Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer4 drops of venipuncture whole blood (approximately 100 uL) to the specimen well(S) of the test device, then start the timer. See illustration below.

    For Fingerstick Whole Blood specimens:

    To use a capillary tube: Fill the capillary tube and transfer approximately 100 uL offingerstick whole blood specimen to the specimen well (S) of the test device, thenstart the timer. See illustration below.
    To use hanging drops: Allow 4 hanging drops of fingerstick whole bloodspecimen(approximately 100 uL) to fall into the center of the specimen well (S) onthe test device, then start the timer. See illustration below.

    3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes.

    tete


    Product detail pictures:


    Related Product Guide:

    Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs forOEM China Reason For High Troponin Levels Supplier –CK-MB test – Laihe, The product will supply to all over the world, such as: Riyadh, kazan, Melbourne, We have a large share in global market. Our company has strong economic strength and offers excellent sale service. We have established faith, friendly, harmonious business relationship with customers in different countries. , such asIndonesia, Myanmar, Indi and other Southeast Asian countries and European, African and Latin American countries.
    email TOP
    privacy settings Privacy settings
    Manage Cookie Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    ✔ Accepted
    ✔ Accept
    Reject and close
    X