Sample type:

    Product Advantage:

    • High Detection accuracy
    • High cost performance
    • Quality assurance
    • Fast delivery
    Our company insists all along the quality policy of "product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff" and the consistent purpose of "reputation first, customer first" for Ivf Pregnancy Test Hcg Levels, Ck Isoenzyme Levels, Troponin Blood Test Normal Range, Our company eagerly looks forward to establishing long-term and friendly business partner relationships with clients and businessmen from all over the world.
    CE Certification Coronavirus Test Kits Suppliers –SARS-CoV-2 Antigen Rapid Test Kit for self-testing (Saliva) – LaiheDetail:

    adv_img

    About COVID-19

    COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are found in a few cases.

    Use this test:

    - If you want to test yourself.
    - If you have symptoms similar to COVID-19, such as headache, fever, cough, sore throat, loss of the sense of smell or taste, shortness of breath, muscle pain.
    - If you are concerned about whether you are infected with COVID-19.
    - Use of the test by persons under 16years of age only under the supervision of an adult.

    Contents:

    A kit contains:
    Package specifications: 1 T/kit, 5 T/kit, 7 T/kit, 25 T/kit
    1) Test device
    2) Buffer with dropper tip
    3) Paper Cup
    4)Disposable dropper
    5) IFU: 1 piece/kit
    5) tubu stand: 1 piece/kit
    Additional required material: clock/ timer/ stopwatch
    Note: Do not mix or interchange different batches of kits.

    Specifications

    Test ItemSample TypeStorage Condition
    SARS-CoV-2 antigenSaliva2-30℃
    MethodologyTest TimeShelf Life
    Colloidal Gold15mins24 months

    Operation

    qw (1)

    01. Rinse and spit with water.
    02. Cough deeply,make the noise of “Kruuua” from the throat to clear sputum/oropharyngeal saliva from deep throat.
    03. Release it into the container once the sputum/oropharyngeal saliva is in your mouth.
    04. Suction 200 microliters through dropper
    05. Into the specimen tube

    qw (2)

    06. Cover the sample tube tightly and shake the sample tube about 10 times
    07. Let stand for 1 minute
    08. Add the sample as follows. Place a clean dropper on the sample tube. Invert the sample tube so that it is perpendicular to the sample hole (S).Add 3 DROPS of the sample.
    09. Set the timer for 15 MINUTES.

    INTERPRETATION

    qw (3)

    POSITIVE: Two colored lines appear on the membrane. One colored line appears in the control region (C) and the other line appears in the test region (T).
    NEGATIVE: Only a single colored line appears in the control region (C). No visible colored line appears in the test region (T).
    INVALID: The control line does not appear. The tests results which do not show a control line after the specified reading time should be discarded. The sample collection should be checked and repeated with a new test. Stop using the test kit immediately and contact your local dealer if the problem persists.
    CAUTION
    1. The color intensity in the test region (T) may vary depending on the concentration of virus proteins present in the nasal mucus sample. Therefore, any color in the test region should be considered positive. It should be noted that this is only a qualitative test and cannot determine the concentration of viral proteins in the nasal mucus sample.
    2. Insufficient sample volume, improper procedure or expired tests are the most likely reasons why the control line does not appear.


    Product detail pictures:


    Related Product Guide:

    While using the "Client-Oriented" company philosophy, a demanding high-quality management method, innovative producing products and also a sturdy R&D workforce, we always deliver premium quality merchandise, superb solutions and aggressive selling prices forCE Certification Coronavirus Test Kits Suppliers –SARS-CoV-2 Antigen Rapid Test Kit for self-testing (Saliva) – Laihe, The product will supply to all over the world, such as: Ireland, Islamabad, South Africa, Based on our automatic production line, steady material purchase channel and quick subcontract systems have been built in mainland China to meet customer's wider and higher requirement in recent years. We are looking forward to cooperating with more clients worldwide for common development and mutual benefit!Your trust and approval are the best reward for our efforts. Keeping honest, innovative and efficient, we sincerely expect that we can be business partners to create our brilliant future!
    email TOP
    privacy settings Privacy settings
    Manage Cookie Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    ✔ Accepted
    ✔ Accept
    Reject and close
    X